Armin Nikzad, BSc; Farid Abbaszade, MSc; Zahra Saghaei, MSc; Soheil Mehdipoor, MD; Firooz Madadi, MD; Morad Karimpoor, PhD
Abstract
Background: Total knee arthroplasty is an accepted method for treatment of osteoarthritis of the knee. Measuring the distal femoral rotation is one of the most important problems in such operations. In the conventional 2D method, measuring the angle is based on CT scan images but these methods usually ...
Read More
Background: Total knee arthroplasty is an accepted method for treatment of osteoarthritis of the knee. Measuring the distal femoral rotation is one of the most important problems in such operations. In the conventional 2D method, measuring the angle is based on CT scan images but these methods usually contain errors. In this study, the three-dimensional measurement of the aforementioned angle was investigated.
Methods: In this research, using CT scans and 3D modeling, 3D lower extremity models of 40 patients were extracted. The rotation of distal femur was measured for plane perpendicular to the anatomical and the plane of mechanical axis of femur. Four axes were drawn on these planes using anatomical landmarks: posterior condylar line (PCL), anatomical and surgical transepicondylar line (ATEA+STEA), and the Whiteside line (WL).
Results: The mean difference of these measurements on the plane perpendicular to the mechanical axis of the femur, between PCL and WL, STEA, ATEA was 3.41, -1.31, 5.53; and angles on the plane perpendicular to the anatomical axis of femur were -0.74, -1.26, and 5.67, respectively. In addition, Bland-Altman diagram was plotted between every two measurements and no relationship found, except for STEA and ATEA.
Conclusions: The measurements between PCL, ATE, and STEA are not affected by the plane on which these measurements are carried out on, except for the 4 degrees difference present in WL axis. With a greater sample size and proper grouping, some relationship might be found between the aforementioned axes.
Pooneh Dehghan, MD; Zahra Saghaei ,MSc; Farid Abbaszadeh, MSc; Morad Karimpour, PhD; Soheil Mehdipoor, MD
Abstract
Background: Femoral neck anteversion is usually measured on the 2-dimensional (2D) images on CT slices. The 3D method uses 3-dimensional model of the femur reconstructed from CT scan images. The aim of this study was to compare these two methods of measurement of femoral ante-version. Methods: In ...
Read More
Background: Femoral neck anteversion is usually measured on the 2-dimensional (2D) images on CT slices. The 3D method uses 3-dimensional model of the femur reconstructed from CT scan images. The aim of this study was to compare these two methods of measurement of femoral ante-version. Methods: In a retrospective study, CT scans of 40 patients (6 men, 34 women) of a teaching hospital in Tehran-Iran were included. Both methods use the same anatomical landmarks, i.e. center of femoral head, femoral neck axis and posterior apex of the femoral condyles. In the 3D method, anteversion angle was measured on a plane perpendicular to the anatomical axis of femur. Whereas in the 2D method the measurement is performed on CT scan slices.Results: Mean anteversion was found to be 9.8 for the 2D and 16.11 for the 3D method. Bland-Altman plot shows that the difference between the two methods is significant.Conclusions: This difference between 2D ad 3D measurement of femoral anteversion may be depend on the level of the selected CT slices, patients positioning during CT examination, and the impact of the deformity. The 3D method eliminates obvious sources of error, namely identifying landmarks and individual orientation of femur. Due to the lack of any gold standard there is a need to further review and study the measurement of this angle.